IGNITION IGNITION TESTS Results: Any reading indicates charge coil or leads are grounded Locate and repair ground, or replace charge coilIf no reading is indicated, go to Output Test
Ohmmeter Test
Note: All ohmmeter tests must be performed with engine NOT runningCalibrate ohmmeterAttach ohmmeter between the two charge coil leadsleads

Output Test
Set peak-reading voltmeter to

"pas" and "500

Attach black lead to one charge coil lead Attach meter red lead to remaining charge coil leadCrank engine and observe meter

Results: Meter must show 610 60 ohmsTo test for grounded condition, connect ohmmeter alternately between each charge coil lead and clean engine ground1Charge coil leads