2004 SR Johnson 4 Stroke 9.9-15HP Outboards Service Manual, Page 103Get this manual

2004 SR Johnson 4 Stroke 9.9-15HP Outboards Service Manual, Page 103

MANUAL STARTER NEUTRAL START INTERLOCK (NSI) CABLE
NEUTRAL START INTERLOCK (NSI) CABLE
Installation Adjustment
1Shift into NEUTRAL position2Install the NSI cable in the clutch lever, the recoil starter, the stopper arm, and the cable bracket3Turn the adjustment nut to align the slot on the stopper arm with the punch mark on the recoil starter case4Make sure that the recoil starter does not work when the shift lever is in FORWARD and REVERSE positions5Tighten the lock nut6Apply Triple Guard Grease Cable ends Cable holding area Cable exit area