IGNITION AND ELECTRICAL STARTER MOTOR Check: Relay operation (Continuity between the relay terminals)

Digital tester Tester selector:

1Disconnect: Relay wires (Y G and B) Cable and wire on terminal G), (2)
Tester probe connection

Probe Terminal G) 2Use 12V Battery3Connect: YellowGreen wireBattery C) Black wireBattery 8
When 12V appliedContinuity When 12V not appliedInfinity

Other probe Terminal (2)