ELECTRICAL CONNECTOR SERVICING
CONNECTOR SERVICING
DEUTSCH Connectors
IMPORTANT: The Deutsch pin and socket terminals are not the same size as Amphenol pin and socket terminalsDO NOT interchange terminalsAlways use the appropriate meter test probes and adapters when testing components fitted with these terminalsIMPORTANT: Electrical Grease is recommendedIncorrect grease application can cause electrical or warning system problemsTo disconnect, press latch and pull connectors apartTo connect the connector, confirm that the seal is in placeClean off any old grease and dirt from connectorsApply light coat of Electrical Grease to sealPush connectors together until latched
Release terminal latch and gently pull on wireTerminal latch (plug)

2Terminal latch (receptacle)

Terminal Installation Push terminal through seal until it locks into placeFill connector with Electrical Grease to 132 in(0.8 mm) below ledge or end of plug