INSTALLATION AND PREDELIVERY INITIAL RUNNING CHECKS
Fuel System
Perform running checks of the fuel system by following these steps: Squeeze fuel primer bulb until hard or activate electric primerObserve all fuel hoses and connectionsRepair any leaks Start outboardVisually inspect all oil hoses and connections and fuel hoses and connectionsRepair any leaks or misrouted hoses immediately
Shift remote control lever to REVERSETurn outboard OFF while lever control is in REVERSEAttempt restarting the outboardOutboard should not start
Tachometer Pulse Setting
The Johnson models included in this manual require "5 Pulse" or "10 Pole" tachometer setting Confirm accuracy of tachometer reading Adjust dial on back of tachometer to required setting (outboard OFF)
Emergency Stop Key Switch
Check emergency stop functionWith outboard running at IDLE, pull safety lanyard from emergency stop switchOutboard must stop immediately
Remote Control Operation