2003 Johnson ST 6/8 HP 4 Stroke Outboards Service Manual, PN 5005471, Page 76Get this manual

2003 Johnson ST 6/8 HP 4 Stroke Outboards Service Manual, PN 5005471, Page 76

IGNITION SYSTEM TESTS Ohmmeter Ground Test To test for grounded condition, connect ohmmeter, alternately, between each jumper and clean engine ground Any needle movement indicates power coil or leads are grounded Locate and repair ground, or replace power coil
Voltmeter Output Test
Set peak-reading voltmeter to POS500Attach voltmeter black lead to one brown coil leadAttach meter red lead to the other brown coil lead
DRC6329

DRC6327

Complete all circuits disconnected during this test
Charge Coil Test
Voltmeter Ground Test
Disconnect two brown wire bullet connectors between coil assembly and power packSet peak-reading voltmeter to POS500Connect the meter black lead to clean engine groundAlternately connect meter red lead between the two brown coil leads