IGNITION COMPONENTS Once the S.L.O.W warning system has activated, crankcase oil pressure must be restored, and the engine must be operated below 1500 RPM before normal operation can be resumedWhen the clip and lanyard assembly is installed, the emergency stop device is in the RUN positionTo stop the engine when the clip and lanyard assembly is in place, press the stop button inward until the engine stops
Ignition Coil
The ignition coil consists of two windings of wire wrapped around laminated steel coreThe coil has primary and secondary terminal connections and ground plate1Power pack

Stop Circuit
The stop button and emergency stop switch are connected to the power pack through the engine wiring harnessWhen activated, these switches direct the power pack output to ground, stopping the ignition systemThe steering handle contains combination stop switchemergency stop device