1999 Evinrude "EE" Electric Outboards Service Manual, P/N 787021, Page 52Get this manual
Continuity TestPositive Circuit12-Volt Hand Control Models
To avoid damaging components or troubleshooting equipment, disconnect the battery cables before proceeding1Use an ohmmeter calibrated on high ohms scale or continuity light to test continuity2Connect one meter lead
to RED battery cable
[] 3Connect second meter lead at circuit breaker :
to RED 8-Ga battery cable
The meter must show continuity If meter shows no continuity, repair or replace battery cable
rn 4Connect switch: meter lead to RED 16-Gawire at second forwardreverse