1999 Evinrude "EE" Electric Outboards Service Manual, P/N 787021, Page 49Get this manual

1999 Evinrude "EE" Electric Outboards Service Manual, P/N 787021, Page 49

Continuity TestPositive Circuit1224-Volt Standard Foot Control Models
INote To avoid damaging components or troubleshooting equipment, disconnect the battery cables before proceeding1Use an ohmmeter calibrated on high ohms scale or continuity light to test continuity2Move 1224-Volt switch to "24 V" position3Connect one meter lead

to RED battery cable to RED 12-Gabattery cable

4Connect second meter lead at 1224-Volt switch:

The meter must show continuity If meter shows no continuity, repair connection or replace battery cable
5Move 1224-Volt switch to "12 V" position6Move first meter lead

to WHITE battery cable to WHITE 12-Gabattery

7Connect second meter lead cable at 1224-Volt switch: