1999 "EE" Outboards Accessories Service Manual, P/N 787026, Page 126Get this manual

1999 "EE" Outboards Accessories Service Manual, P/N 787026, Page 126

8 DR1798

Trim-INTilt-OOWN Mode
[] When the hydraulic unit is in the trim-in tilt-down mode, the hydraulic fluid is routed in the following manner: 1Hydraulic pressure is directed to the reverse lock check valve causing the piston to open the trim check valve
side of the pump control piston ,

2Fluid then opens the reverse lock check valve against very light spring tension and flows through the valve to the top of the trim and tilt cylinders3Fluid returning from the bottom of the tilt cylinder opens the trimtilt separation valveflows through the open valve, then through the open trim check valve, and back to the pump4Fluid returning from the bottom of the trim cylinders flows through the open trim check valve and back to the pump5Because of the volume of fluid displaced by the tilt and trim rods, less fluid is required above the tilt and trim pistons than is being supp lied to the pump from beneath the pistonsSome of the fluid from the outlet side of the pump is returned to the reservoir through the trim-down pump relief valve 6.lfthe switch is held in the down position after the trim and tilt rods are retracted, the pressure buildup will open the trim-down pump relief valve, and the fluid will be directed back to the reservoirThis valve opens at approximately 800 PSI (4200 kPa)III ID