Relay Ohmmeter Tests
The orientation and location of the UP and DOWN relays in the bracket will vary from model to model, but the relay terminals are always connected to the electrical system and trim motor as follows: S
= Switch (+ or -)
Wire ColorBlueWhite, GreenWhite, or Black B+12 Volt (+) Battery Wire ColorRed BM
12 Volt (-) Battery (Ground) Wire ColorBlack Motor Wire Color
Blue or Green
To protect your test light or ohmmeter, remove relays from sockets before proceeding with test1Use an ohmmeter calibrated on high ohms scale or continuity light to test continuity2Connect meter leads to relay terminals "B-" and "M" The meter must show continuityDR3950