Starter RelayRelay Function Test Use this test to identify the cause of no-cranking problem1Connect voltmeter black lead to ground, and red lead to battery side of relayMeter should show battery voltage YESGo to Step NOCheck condition of battery, battery connections, and battery switch

2Disconnect yellowgreen wire bullet connectorConnect voltmeter red lead to yellowgreen wire (ignition side) and black lead to groundTurn key switch to START positionmeter should show battery voltage YESGo to Step NOCheck both neutral switches, key switchand wiring and connectors in between
11!1 3Reconnect yellowgreen wire bullet connectorMove me YESCheck wiring and connections to starter, and starter groundReplace starter motor