1999 "EE" Evinrude 200, 225 V6 FFI Outboards Service Manual, P/N 787025, Page 139Get this manual

1999 "EE" Evinrude 200, 225 V6 FFI Outboards Service Manual, P/N 787025, Page 139

Charging System Tests Variable load Tests For Cranking Battery To test the operation of the rectifierregulator, you must be able to run the engine continuously at approximately 2000 RPM, such as in test tank or on marine dynamometerThe test consists of monitoring the system's response to partially discharged batteryUse variable load tester to discharge the battery50

Alternator Output

INote The rectifierregulator requires battery voltage on the red
lead to operateBefore proceeding, verify battery voltage at rectifierregulator red lead when key is ON 1Disconnect battery cables
DRC7617

2Connect 0-40 amp ammeter in series between the main power relay red lead and the battery side of the starter solenoid3Reconnect the engine's battery cables