1999 "EE" Evinrude 200, 225 V6 FFI Outboards Service Manual, P/N 787025, Page 84Get this manual

1999 "EE" Evinrude 200, 225 V6 FFI Outboards Service Manual, P/N 787025, Page 84

CVerify switched B+ at purplewhite wire, terminalJ", of Power Distribution Panel 14-pin connectorThere should be more than 9.5 volts while cranking, or more than 13 volts while running OKverify 40-volt systemGo to Step No voltagetest stop circuitSee Step of Action StepsIgnition System in this section Low voltage:Verify battery capacity, condition, and connections- Test current draw of starter motorSee Section 7
[] DVerify 40-volt system by checking voltage at fuses in Positions 2, 3, and 6Check for any of the following: Key ONengine not runningabout volt less than battery voltage Crankingapproximately 20V Engine runningmore than 24 volts and steady at idleMore than 39V and steady above 1500 RPMResults: As specifiedcheck supply voltage at injectorGo to Step Any less than specifiedtest charging system and start assist circuitSee Step 8[] ECheck injector supply voltage at the white or striped-white leads of each injector connector