1998 Johnson Evinrude "EC" 90, 115 SPL Service Manual, P/N 520209, Page 241Get this manual
Stator Resistance Tests INotel Disconnect battery cables before proceeding with this check
1Disconnect stator yellow and yellowgray leads from terminal board2Calibrate ohmmeter on appropriate scaleConnect one ohmmeter lead to stator yellow lead and the other ohmmeter lead to stator yellowgray lead Refer to chart below for the correct value for your engine and stator combination
Repair or replace stator if reading is not correct
3To check for grounded condition, disconnect both ohmmeter leadsCalibrate ohmmeter on appropriate scaleConnect one ohmmeter lead to clean engine ground and the other ohmmeter lead alternately to both stator leads Ohmmeter should show high reading If ohmmeter shows low reading, stator is grounded and should be repaired or replacedRefer to Stator Servicing, Section 3DR4034