Shift Cable AdjustmentRemote Control Models
11 The shift cable must be adjusted correctly or water pressure
from forward boat travel could move the gate into REVERSE, causing the boat to stop abruptlyOccupants could be thrown about or ejected

1Pull up on shift cam until cam roller is at the far end of the FORWARD detent range 2Shift remote control to FORWARD positionTemporarily push cable guide onto shift cam stud Pull firmly on cable casing to remove free-playAdjust cable trunnion to align with trunnion anchor bracket Pull cable off the stud
3Insert cable trunnion in anchor bracket and turn 90 to lock the trunnion in place4Push cable guide onto stud Install washer and hand tighten the locknut

5Shift remote control to NEUTRALThe cam roller should snap into NEUTRAL detent when you pull up on the reverse gate with moderate pressure6If you cannot achieve NEUTRAL detent, lengthen cable slightly and recheck your adjustment