7 DR4098 DR4099

STEPCHARGE COIL TESTS
Ground Test

[] 1Disconnect 2-pin Amphenol connector between the stator and power pack2Set peak-reading voltmeter to "POS" and "500"[] 3Alternately, connect voltmeter between stator connector terminals "A", "8", and clean engine groundCrank engine and observe meter at each connection Any reading on either test indicates charge coil is grounded Locate and repair ground, or replace stator assembly4If no reading is indicated in Step 3, go to Output TestOutput Test