1998 Johnson Evinrude "EC" 90, 115 SPL Service Manual, P/N 520209, Page 102Get this manual

1998 Johnson Evinrude "EC" 90, 115 SPL Service Manual, P/N 520209, Page 102

Principles of Operation Flywheel

The flywheel contains the permanent magnets necessary to energize the sensor and charge coilsOnce the flywheel exceeds minimum cranking RPM, the flywheel's magnetic lines of force passing through the sensor and charge coil windings produce voltage in those circuitsWhen the flywheel is in good condition and correctly located, it controls ignition timing and charge coil output The sensor magnets are in ring around the flywheel hub and the charge coil magnets are in the flywheel rim