1998 Johnson Evinrude "EC" 90, 100C, 105C, 115, 150, 150C, 175 60 deg. LV Service Manual, P/N 520210, Page 291Get this manual

1998 Johnson Evinrude "EC" 90, 100C, 105C, 115, 150, 150C, 175 60 deg. LV Service Manual, P/N 520210, Page 291

Charging System Check Chart Where to Look Cause Procedure Reference

Battery

1Battery defective or worn out 2Low electrolyte level 3Terminal connections loose or corroded 4Excessive electrical load

1Check condition and charge 2Add water and recharge 3Clean and tighten 4Evaluate accessory loads 1Clean and tighten 2Perform ohmmeter tests 3Perform ohmmeter tests 1Perform ohmmeter tests 2Perform running output tests 3Perform ohmmeter tests 1Perform variable load tests