Cranking Discharge Method
1Check battery voltage If voltage is greater than 12.5 volts, go to Step If voltage is less than 12.5 volts, go to Step 32Separate the ignition charge coil connector(s)Crank engine in short bursts until battery voltage is less than 12.5 voltsCheck battery voltage with key in the OFF position
INote Disconnect engine battery cables before proceeding with