1998 Johnson Evinrude "EC" 40 thru 55 2-Cylinder Service Manual, P/N 520206, Page 314Get this manual

1998 Johnson Evinrude "EC" 40 thru 55 2-Cylinder Service Manual, P/N 520206, Page 314

Routine Inspections 1Check reservoir fluid level at least once per season or every 100 operating hoursSystem capacity is approximately 11.7 flo oz(345 mil: Tilt the motor and engage the trail lock levers Support the engine's weight with suitable hoist Remove the fill plug[]] Add OMC Power TrimlTilt and Power Steering Fluid or GM Dexron II, as needed, to bring its level to the bottom of the fill plug threads Install the fill plug and torque to 45-55 inIbs(5-6 Nml Disengage the trail lock levers and the hoist Cycle the unit at least five complete cycles to purge all air from the systemWhen cycling the unit, hold the trim switch ON an additional to 10 seconds after the unit reaches the end of its travel before activating the switch in the opposite direction 2Check the manual release valve with torque wrenchThe valve must be torqued to 45-55 inIbs(5-6 Nm)3Check for external signs of fluid leakageCorrect causes as necessary4Inspect the stern brackets for binding with the swivel bracket in the thrust rod areaRetorque the tilt tube nuts as follows: Tighten the tilt tube nuts to torque of 40-45 ftIbs(54-60 Nml Loosen one nut