1998 Johnson Evinrude "EC" 40 thru 55 2-Cylinder Service Manual, P/N 520206, Page 75Get this manual

1998 Johnson Evinrude "EC" 40 thru 55 2-Cylinder Service Manual, P/N 520206, Page 75

DRC7006
VRO Oil Pump Volume Test
For functional tests of the VRO pump, refer to Testing Fuel System, this sectionTo verify oil delivery and proper fueloil ratio:
Avoid accidental starting of engine while changing propellers; twist and remove all spark plug leads1Install the proper test propeller and put the engine in suitable test tank2Start the engine and allow it to reach normal operating temperatureStop the engine
I Note Push fuel hose off fuel fittingsdon't pullIf pushing won't separate hose from fitting, carefully

cut the hose along its side and peel it back to avoid damaging the fittings3Carefully remove the oil supply hose from the VRO pump oil inlet fitting

4Install 10 in(25 cm) length of 1f4 in(6,35 mm) I.Dclear vinyl hose with marks every mm) for in(101,6 mm)starting several inches from the open end

5Fill the hose with Evinrude or Johnson Outboard Lubricant and run the engine to eliminate air from the base of the hose and VRO pumpShut off the engine and add oil to the hose until its level is above the highest mark6Run engine at about 1500 RPM and monitor the pump cycles by using fuel pressure gauge or putting light finger pressure on the outlet hoseCount the pulses for the oil level to drop in(76 mm)The pump should pulse to times for in (76 mm) oil level drop in 1f4 in(6,35 mm) I.Dhose7If your results are different, check the pulse limiter before repairing the pump8If you remove pump, push the hoses off or carefully cut the hose along the side of the fitting to remove the hose without damaging the fitting9Install the oil supply hose using spring clampTorque the pump-to-bracket screws to 18-24 inIbs(2-3 Nm)INotel When installing oil supply hose, be sure connections are airtightAn air leak in the oil supply