Once the S.L.DWwarning system has activated, the engine must cool to allow the temperature switch to open or outboard lubricant must be added to the oil tankThe engine must be operated below 1500 RPM before normal operation can be resumedThe ignition module also incorporates QuikStart electronic starting, which automatically advances the ignition timing when the engine temperature is less than 1050 (4P el, and for approximately seconds each time the engine is started, to ensure reliable startsStop CircuitRope and TE Models
The stop buttonkey switchand emergency stop switch are connected to the ignition module through the engine wiring harnessWhen activated, these switches direct the ignition module output to ground, stopping the ignition systemThe steering handle contains combination stop switch emergency stop device When the clip and lanyard assembly is removed, the emergency stop device is in the STOP position When the clip and lanyard assembly is installed, the emergency stop device is in the RUN position To stop the engine when the clip and lanyard assembly is in place, press the stop button inward until the engine stopsKey Switch