1998 Johnson Evinrude "EC" 2 thru 8 Service Manual, P/N 520202, Page 244Get this manual

1998 Johnson Evinrude "EC" 2 thru 8 Service Manual, P/N 520202, Page 244

AC Lighting Coil Resistance Check

1Calibrate an ohmmeter on appropriate scaleConnect it between yellowgray and yellow leads Meter must show 0.86 0.05
rn 2Connect meter between yellowgray and yellowblue leads

Meter must show 1.21 0.02

nDR41S9

3Calibrate ohmmeter on appropriate scaleConnect one lead to clean engine ground Probe each of the connector pins with the other ohmmeter jumper wire The ohmmeter should show high reading If the ohmmeter reading is low, repair the grounded coil lead or replace the stator assemblyRefer to Section for ignition plate servicing