1998 Johnson Evinrude "EC" 2 thru 8 Service Manual, P/N 520202, Page 241Get this manual

1998 Johnson Evinrude "EC" 2 thru 8 Service Manual, P/N 520202, Page 241

Running Test, Alternator Output
INote Disconnect
battery cables before proceeding with this

1Remove the rectifier red lead from the terminal board2Wire 0-40 amp ammeter in series with the rectifier red lead and the wiring harness red lead
1 1111fitll
1000 2000 3000 4000 5000 6000

Guard against any red wire, its terminals, or the ammeter coming in contact with engine ground while the engine is running Contact could cause arcing3The eng ine's battery should not be fully charged when begin ning this testConnect the battery cables and run the engine in test tankRefer to the output curves to determine the correct output-to-RPM ratio for your engine If there is no output or the output is not correct, refer to the stator and rectifier ohmmeter tests in this section