1998 Johnson Evinrude "EC" 2 thru 8 Service Manual, P/N 520202, Page 121Get this manual

1998 Johnson Evinrude "EC" 2 thru 8 Service Manual, P/N 520202, Page 121

Ohmmeter Test
INote All ohmmeter tests must be performed with engine NOT running1Calibrate an ohmmeter on appropriate scale

2Attach ohmmeter leads between the two sensor leads Meter must show 100 15 ohms
I1II 3To test for grounded condition, connect ohmmeter alternately between each sensor lead and a