1998 Johnson Evinrude "EC" 2 thru 8 Service Manual, P/N 520202, Page 107Get this manual

1998 Johnson Evinrude "EC" 2 thru 8 Service Manual, P/N 520202, Page 107

10 DR4619

Ohmmeter Test INotel All ohmmeter tests must be performed with the engine NOT running
rn 1Insert jumper wires in ignition plate connector, terminals "A" and "0"rn 2Calibrate ohmmeter on appropriate scaleConnect between jumpers Meter must show 900 100 ohms

3To test for grounded condition, connect ohmmeter alternately between each jumper and clean engine ground Any needle movement indicates charge coil or leads are grounded Locate and repair ground, or replace charge coil