1998 Johnson Evinrude "EC" 150, 175 FFI Service Manual, P/N 520211, Page 137Get this manual

1998 Johnson Evinrude "EC" 150, 175 FFI Service Manual, P/N 520211, Page 137

Stator Resistance Tests
INote Disconnect battery cables before proceeding with this test

1Disconnect stator 26-volt yellowblue, yellow, and yellow gray stripe wires from rectifierregulator port sideStator 26-volt wires are the shorter length wires2Connect one meter lead to stator wire and the other meter lead to another wire

3Alternate meter leads to test all combinations of stator wires
4To check for grounded condition, connect one meter lead to ground wire and alternately connect the other meter lead to each stator 26-volt wires Meter should read no continuity If meter reads continuity, the stator is grounded5Repeat Steps thru for stator 12-volt (longer length) yellow blue, yellow, and yellowgray stripe wiresStator 12-volt wires connect to rectifierregulator starboard side