RectifierRegulator Tests Variable Load Tests To test the operation of the rectifierregulator, you must be able to run the engine continuously at approximately 4500 RPM, such as in test tank, on marine dynamometer, or on the boatThe test consists of monitoring the system's response to partially discharged batteryTwo methods for performing this test are described belowVariable Load High Rate Discharge Method

INote The

rectifierregulator requires battery voltage from the purple lead to operateBefore proceeding, verify battery voltage at terminal strip purple leads when key is ON1Disconnect battery cables

2Connect 0-40 amp ammeter in series between the rectifierregulator red lead and the battery side of the starter solenoid
3Reconnect the engine's battery cables
Following the manufacturer's directions, connect the variable load tester (carbon pile) across the battery terminalsStevens Model NoLB-85 and Snap-on Model NoMT540D are examples of testers availablecausing electrolyte gassingThis might create an explosive atmosphere5Start the engine and run it at approximately 4500 RPMUse the variable load tester to draw the battery down at rate equivalent to the stator's full output The ammeter should indicate nearly full outputor 35 amps