1998 Johnson Evinrude "EC" 125C, 130, 200, 225, 250 90 deg LV Service Manual, P/N 520212, Page 353Get this manual
Solenoid Tests
INote All engine wiring must be disconnected from the solenoid
before proceeding with this test
1Calibrate ohmmeter on appropriate scaleConnect one lead to terminal and the other lead to terminal Ohmmeter should show high reading If the ohmmeter shows low reading, replace the solenoid
2With the ohmmeter still connected as described in Step 1, attach positive battery jumper to terminal and negative battery jumper to terminal The solenoid should close with an audible click The ohmmeter should show low reading If the ohmmeter shows high reading, replace the solenoid
3After installing the solenoid, coat all wires and terminals with
OMC Black Neoprene Dip
No Load Current Draw, Electric Starter
INote Securely fasten
starter in vise or other suitable fixture before proceeding with this check1Locate battery rated at 500 CCA (60 amp-hr) or higher that is in good condition and fully charged