1998 Johnson Evinrude "EC" 125C, 130, 200, 225, 250 90 deg LV Service Manual, P/N 520212, Page 352Get this manual

1998 Johnson Evinrude "EC" 125C, 130, 200, 225, 250 90 deg LV Service Manual, P/N 520212, Page 352

High Voltage

In some conditions, the key switch may be shorting (allowing some leakage) to the other terminals in the key switch, but will not show up with test light or an ohmmeterThis condition may be found by using condenser tester (leakage test) where voltage of approximately 500 volts is applied to the key switch terminalsWith all leads disconnected and the key switch in the OFF position, connect the black lead of the tester to one of the JIM" terminals of the key switch1Attach the red lead of the tester to the JIB" terminal and apply leakage test2Repeat test by moving the red lead to each of the terminals and applying the leakage testThe meter will indicate if leakage is present