1998 Johnson Evinrude "EC" 125C, 130, 200, 225, 250 90 deg LV Service Manual, P/N 520212, Page 201Get this manual

1998 Johnson Evinrude "EC" 125C, 130, 200, 225, 250 90 deg LV Service Manual, P/N 520212, Page 201

Temperature Switch Test Purpose One heat sensitive switch is installed in each cylinder head to monitor engine temperatureBoth switches are connected in series with the warning systemIf either switch senses tempera ture in excess of predetermined limit, contacts close and cause the System Check gauge "WATER TEMP" light to turn on and the warning horn to sound for ten seconds
INote To ensure that the temperature sensing system

can alert the operator during an overheating condition, test the warning system as described in Section 7, System Check Engine Monitor
Testing

1Disconnect the temperature switch wire connectorRemove the temperature switch from the cylinder head
2Using continuity light or ohmmeter, make positive connections to the switchone lead to the switch lead and one lead to the metal portion of the switch