1998 Johnson Evinrude "EC" 125C, 130, 200, 225, 250 90 deg LV Service Manual, P/N 520212, Page 164Get this manual

1998 Johnson Evinrude "EC" 125C, 130, 200, 225, 250 90 deg LV Service Manual, P/N 520212, Page 164

DRC6144 DRC6145

Ohmmeter TestStop Circuit

rn rn rn rn

All ohmmeter tests must be performed with the engine NOT running
1Attach clip and lanyard to emergency stop switch 2Separate the 2-pin Amphenol connector between power pack and key switch3Separate the 1-pin Amphenol connector

between engine wiring harness and shift switch
4Calibrate ohmmeter on appropriate scale
5Connect meter black lead to clean engine groundConnect meter red lead to connector terminal liB" (blackyellow) wire Key OFF, meter must show low resistance Key ON, meter must show high resistance6If Step key ON reading is low one, disconnect harness blackyellow lead from key switch "M" terminal If meter now shows high reading, replace key switch If meter shows low reading, go to Step 7