1997 Johnsoon Evinrude "EU" 50 thru 70 3-Cylinder Service Manual, P/N 507266, Page 117Get this manual

1997 Johnsoon Evinrude "EU" 50 thru 70 3-Cylinder Service Manual, P/N 507266, Page 117

Timer Base Servicing Removal

& To avoid accidental starting of engine while servicing, twist
and remove all spark plug leads
1Remove the stator assemblyRefer to Stator Servicing2Disconnect the timer base connector
rn 3Remove the screws securing the timer base retaining clips
Remove the timer baseInstallation

1Carefully inspect the crankcase head and timer base bushing for dirt, metal chips, or scratches
rn 2.bearing surfacecoating of OM:: Moly Lube to the crankcase Apply light and the timer base bushinghead