Continuity TestPositive Circuit12-Volt Hand Control Models INotel To avoid damaging components or troubleshooting equipment, disconnect the battery cables before proceeding 1Use an ohmmeter calibrated on high ohms scale or continuity light to test continuity2Connect one meter lead to RED battery cable

3Connect second meter lead at circuit breaker:

to RED 8-Ga
battery cable

The meter must show continuity If meter shows no continuity, repair or replace battery cable
rn 4Connect switch: meter lead to RED 16-Gawire at second forwardreverse
The meter must show continuity If meter shows no continuity, replace circuit breaker5Move forwardreverse switch to FORWARD