1997 Johnson Evinrude "EU" Accessories Service Manual, P/N 507270, Page 61Get this manual

1997 Johnson Evinrude "EU" Accessories Service Manual, P/N 507270, Page 61

Battery Charging Boost charge 12-volt batteries at 50 amperes for 20 minutes (1000 ampere minutes)If the charger will not give this rate, charge for an equal number of ampere minutes at best rate availableDO NOT boost battery more than this amount for the "Iight load test If batteries are to be fully charged by means of quick charger, the charge rate must be "tapered" (reduced to safe limit) when the electrolyte temperature reaches 1250 (52 C), or when gassing becomes excessiveFailure to do so may harm the batteryIf the battery is to be slow charged, adjust electrolyte to proper level by adding water, then charge the battery at amperes until fully chargedFull charge of the battery is indicated when all cell gravities do not increase when checked at three intervals of one hour and all cells are gassing freelyPlenty of time must be allowed for slow chargingCharge periods of 24 hours or more might be required