1997 Johnson Evinrude "EU" 90 thru 115 90 CV Service Manual, P/N 507267, Page 220Get this manual

1997 Johnson Evinrude "EU" 90 thru 115 90 CV Service Manual, P/N 507267, Page 220

Shift Cable AdjustmentRemote Control Models
&The shift cable must be adjusted correctly or water pressure from forward boat travel could move the gate into REVERSE, causing the boat to stop abruptlyOccupants could be thrown about or ejected[!Q]
1Pull up on shift cam until cam roller is at the far end of the FORWARD detent range 2Shift remote control to FORWARD positionTemporarily push cable guide onto shift cam stud Pull firmly on cable casing to remove free-playAdjust cable trunnion to align with trunnion anchor bracket Pull cable off the stud'-L==",.J

3Insert cable trunnion in anchor bracket and turn 90 to lock the trunnion in place4Push cable guide onto studInstall washer and hand tighten the locknut

5Shift remote control to NEUTRALThe cam roller should snap into NEUTRAL detent when you pull up on the reverse gate with moderate pressure6If you cannot achieve NEUTRAL detent, lengthen cable slightly and recheck your adjustment