Deutsch Connector Servicing INotel The Deutsch pin and socket terminals are not the same size as Amphenol pin and socket terminalsYou cannot interchange themDisconnect

Press latchpull connectors apartConnect

Check that seal is in placeClean off old greasedirt from connectorsApply light coat of OMC Electrical Grease to sealPush connectors together until latched

Terminal Removal

Use hook-end of OMC Connector Service Tool, PIN 342667, to pull out wedge from receptacle, or use other end of tool to pry out wedge from plugUse needle-nose pliers to remove wedge from 3-pin receptacle42327

rn Release terminal latch orgently pull on wireTerminal Installation

Push terminal through seal until it clicks into placeTwist and tug wire if no click is heardFill connector with OMC Electrical Grease to 132 in(0,8 mm) below ledge or end of plug 42329