No Load Current Draw, Electric Starter
INote Securely fasten

starter in vise or other suitable fixture before proceeding with this check1Locate battery rated at 500 CCA (60 amp-hr) or higher that is in good condition and fully charged

2Connect 0-100 amp ammeter in series with heavy jumper between the battery "+" terminal and the starter "+" terminal
3Attach or hold vibration tachometer, such as Frahm Reed tachometer, to the starter4Complete the circuit with heavy jumper between the battery "-" terminal and the starter frame5Monitor the starter RPM and current draw and refer to the chart below for the correct specificationsNo Load Current Draw Specifications Model Voltage Amps (Maximum) RPM