1997 Johnson Evinrude "EU" 90, 105RW, 115, 150, 150W, 175 60 LV Service Manual, P/N 507268, Page 278Get this manual
No Load Current Draw, Electric Starter
INote Securely fasten
starter in vise or other suitable fixture before proceeding with this check1Locate battery rated at 500 CCA (60 amp-hr) or higher that is in good condition and fully charged
2Connect 0-100 amp ammeter in series with heavy jumper between the battery "+" terminal and the starter "+" terminal
3Attach or hold vibration tachometer, such as Frahm Reed tachometer, to the starter4Complete the circuit with heavy jumper between the battery "-" terminal and the starter frame5Monitor the starter RPM and current draw and refer to the chart below for the correct specificationsNo Load Current Draw Specifications Model Voltage Amps (Maximum) RPM