In 824005 DRCS887
DRCS888

",fi' !!)DRCS889
DRCS891

Key Switch Tests

Ohmmeter or Continuity Light

1Disconnect battery leads and leads at the key switch
2With key switch in OFF position, connect continuity light or meter leads between key switch "BATT" and "A" terminalsLight or meter should not show continuity
rn 3.continuityswitch to ON position Light or meter should Turn key show rn show continuityto START positionLight or meter should 4Turn key switch still5With key held in START position, transfer lead from "A" terminal to "S" terminalLight or meter should still show continuity[] 6Transfer leads to "M" terminalsLight or meter should not show continuity in START or ON positionsDRCS892