1997 Johnson Evinrude "EU" 9.9 thru 30 2-Cylinder Service Manual, P/N 507263, Page 136Get this manual

1997 Johnson Evinrude "EU" 9.9 thru 30 2-Cylinder Service Manual, P/N 507263, Page 136

Engine Temperature Check The Markal Thermomelt Stik is heat sensitive marker that melts on contact with surface of specific temperatureOne source for Thermomelt Stiks is Stevens Instrument Company

At least two Thermomelt Stiks or digital pyrometer should be used to accurately determine the engine's operating temperatures-:-:1

The Thermomelt Stik mark will appear dull and chalky when the surface marked is below the Stik's rated temperatureWhen the surface exceeds the Stik's rated temperature, the mark will appear liquid and glossy
To achieve accurate and consistent readings, engine temperature must be gauged at the top of cylinder head
INotel For the following engine operating temperatures and RPM figures to be correct, the inlet water temperature must be 70 100 (21 30 e)Pyrometer Procedure 1Install correct test propeller and place engine in test tank