1997 Johnson Evinrude "EU" 9.9 thru 30 2-Cylinder Service Manual, P/N 507263, Page 109Get this manual

1997 Johnson Evinrude "EU" 9.9 thru 30 2-Cylinder Service Manual, P/N 507263, Page 109

Power Test
INotel Do not exceed the coil's maximum specified amperage when testi ng it
rn The ignition coilred lead to the primary terminal ofconnecis tested with "normal" polarity the coil tionsConnect tester
and the tester black lead to the ground tab Connect the high tension lead of the tester to the coil spark plug lead steady spark, in the tester at or before maximum specified amperage, indicates good coilRefer to Ignition Coil Specifica-

tionsSurface Leakage Test

INotel Do not exceed the coil's maximum specified amperage when testing it
The ignition coil and spark plug lead should be tested for leakage and insulation failures using the ignition testerLeakage is caused by moisture, cracks, or holes in the coil housing or spark plug leads[] With the tester's small black and red leads still connected, remove the tester's high tension lead from the coilTurn on the tester and probe entire surface of the coil, spark plug lead, and spark plug coverFlashover will be apparent wherever insulation has broken downReplace any coil or spark plug lead that shows leakage