1997 Johnson Evinrude "EU" 125C, 130, 200, 225, 250 90 LV Service Manual, P/N 507269, Page 366Get this manual

1997 Johnson Evinrude "EU" 125C, 130, 200, 225, 250 90 LV Service Manual, P/N 507269, Page 366

Cranking Discharge Method
1Check battery voltage If voltage is greater than 12.5 volts, go to Step If voltage is less than 12.5 volts, go to Step 32Separate the ignition charge coil connectorsCrank engine in short bursts until battery voltage is less than 12.5 voltsCheck battery voltage with key in the OFF position
INote Disconnect engine battery cables before proceeding with
this check3Connect 0-40 amp ammeter in series between the rectifier regulator red lead and the battery side of the starter solenoid4Reconnect the engine's battery cablesReconnect the ignition charge coil connectors