20Apply OMC Gasket Sealing Compound to the threads of the shift rod cover screwsInstall the screwsTighten the screws to 60-84 inIbs(7-9 Nm)21Position the driveshaft thrust bearingthrust washerand shim(s) (selected earlier) on the driveshaftin the order shown

[!!J INote Position bearingwasherand shim(s) exactly
22Lightly apply OMC Gasket Sealing Compound to the gearcase area that contacts mounting flange of the bearing housingDo not coat inside bearing housing bore surface of the gearcase23Using OMC Driveshaft Seal Protector, PIN 318674, slide the driveshaft bearing housing onto the driveshaft24Pull up on the shift rod to engage FORWARD gearTurn the gearcase upside down by rotating the holding fixtureBe sure any excess grease is removed from the pinion needle bearingsDegrease inside taper of the pinionPosition the pinion in the gearcase25Degrease the driveshaft taper and install the driveshaftTurn the gearcase right side upCOA3130