7 DR4045

Ohmmeter Test

All ohmmeter tests must be performed with engine NOT running
[] 1Insert jumper wires in stator connector, terminals "A" and "8"2Calibrate ohmmeter on appropriate scaleConnect between the two jumper wires Meter must show 480 50 ohms

3To test for grounded condition, connect ohmmeter alternately between each jumper and clean engine ground Any needle movement indicates the charge coil or leads are grounded Locate the ground and repair, or replace the stator assembly4Complete all circuits disconnected during this test