1997 Johnson Evinrude "EU" 125C, 130, 200, 225, 250 90 LV Service Manual, P/N 507269, Page 166Get this manual

1997 Johnson Evinrude "EU" 125C, 130, 200, 225, 250 90 LV Service Manual, P/N 507269, Page 166

Sensor Coil Ohmmeter Test INotel All ohmmeter tests must be performed with engine NOT

running
r:m is the" +"proceeding, you meter verify that the ohmmeter red 1Before must lead leadCalibrate on appropriate scaleAttach
to known good diode as shown Meter must show low reading When meter leads are reversed, meter must show high reading2If your test results are opposite, reverse internal meter lead connections so the red lead represents" +"

3Attach ohmmeter red lead to port timer base connector, terminal "0"
4Alternately, attach ohmmeter black lead to port connector, terminals "A", "B", and "C", and starboard connector, terminals "A", "B", and "C"Meter reading at each connection should be:
Stevens AT-101 meter: 360 30 ohms Merc-O-Tronic M-700 meter: 970 100 ohms Fluke 29 Series II meter: 975 100 ohms