Starter Circuit CheckRemote
INote Battery must be fully chargedStep Procedure Result aIf no reading, go to Step

&Check voltage between ground Steps thru Remove starter to solenoid cable from l to prevent starter engagement while making checksvoltage between ground

DConnect voltmeter between D

Remove black lead from ground at

and common engine groundTurn key to START positionVoltmeter should show battery voltage
bIf meter reads battery voltage, reconnect black lead to ground and go to Step

II Check

INote Steps II thru II -

Connect meter at START position

Turn key to

aIf meter reads battery voltage, lead is open between D and

Turn key OFF before connecting and disconnecting meterTurn key to START position after connectingvoltage between ground Connect meter at Turn key to START position