1996 Johnson/Evinrude Outboards 50 thru 70 3-Cylinder Service Manual, Page 241Get this manual

1996 Johnson/Evinrude Outboards 50 thru 70 3-Cylinder Service Manual, Page 241

Starter Circuit CheckTTL
To avoid accidental starting of engine, disconnect starter cable at G)
INotel Engine must be in NEUTRAL throughout test procedureBattery must be fully charged

Procedure Connect voltmeter between cable at G) and groundTurn key switch to ON positionPress start button Connect voltmeter between and ground
Results If meter shows 12 volts, test starter If meter shows volts, go to Step

Check voltage to cable at G)
Check voltage at

If meter shows 12 volts, go to Step

If meter shows volts, test battery and cablesConnect voltmeter between and ground Press start button If meter shows 12 volts, go to Step I) If meter shows volts, test sta rt button, key switch, and iri ng Disconnect solenoid ground lead Check voltage at If meter shows 12 volts, proceed to Step