1996 Johnson Evinrude "ED" Electric Outboards Service Manual, P/N 507119, Page 46Get this manual

1996 Johnson Evinrude "ED" Electric Outboards Service Manual, P/N 507119, Page 46

Speed Control SwitchHBF2 Models
INote To avoid damaging components or troubleshooting equipment, disconnect the battery cables before proceeding 1Remove speed control switch from foot pedalRefer to Rotary Switch Service, Section 7, for disassembly information2Unsolder and remove the RED, GREEN, and GREENWHITE wires from terminals "2" thru "4" of the speed control switch 3Use an ohmmeter calibrated on high ohms scale or continuity light to test continuity
4Connect one meter lead to terminal "A" for all of the following testsWith the switch OFF, the meter must show no continuity between terminal "A" and terminals "2" thru "4"5At no time should the meter show continuity between any terminal and the metal switch case6With the switch at speed 1: