1996 Johnson Evinrude "ED" Electric Outboards Service Manual, P/N 507119, Page 39Get this manual

1996 Johnson Evinrude "ED" Electric Outboards Service Manual, P/N 507119, Page 39

1224-Volt SwitchStandard Foot Control Models
I Note To avoid damaging components or troubleshooting equipment, disconnect the battery cables before proceeding 1Use an ohmmeter calibrated on high ohms scale or continuity light to test continuity
rn With switch at 24 volts, meter must show continuity when connected between the two leadsRED

switch at 12 volts, meter must show continuity when connected between the center RED lead and the

Meter must show no continuity between any lead and the switch's metal case2Replace switch if your test results are different3Refer to Section for assembly information1224-Volt SwitchHand Control Models

INotel To avoid damaging components or troubleshooting equipment, disconnect the battery cables before proceeding1Remove the steering housing cover[] 2Use lS inAllen wrench to remove the control shaft set screwRemove the control shaft and forwardreverse lever to access the 1224-volt switch